BASE Industrial Systems
Service · 04 / 06

Power & Load Monitoring

Real-time energy and power-quality data to drive uptime and tariff decisions.

Overview

We deploy revenue-grade metering and power-quality analysers to capture true-RMS demand, harmonics and unbalance across your network. Data feeds into dashboards that surface peak demand, power factor, and N+E imbalance — so you can act before NMI charges or equipment failures bite.

01 · Service

Data you can act on

We've yet to see a site that wasn't paying for something it didn't know about — soft starter inrush hitting demand windows, idle MCCs running PFC mis-tuned, a single VSD pushing 8% THD through the upstream transformer. Metering finds it. Dashboards prove it. The reports tell you what it's worth to fix.

02 · Service

Integration without lock-in

Our monitoring rides standard protocols — Modbus TCP, BACnet/IP, MQTT, OPC-UA — and feeds your existing SCADA, BMS or cloud platform. We're happy to deliver a turn-key Grafana stack, or hand the tags off to your integrator. No proprietary gateway lock-in.

Scope of work

Built to spec, every line.

  • 01
    Class 0.5S revenue-grade metering
  • 02
    Harmonics analysis to the 50th order (IEEE 519)
  • 03
    Modbus TCP / BACnet / MQTT / OPC-UA integration
  • 04
    Cloud or on-prem dashboards (Grafana, PowerBI)
  • 05
    Tariff modelling, demand-shifting and payback reports
  • 06
    Sub-circuit metering for PUE and tenant billing
Technical specification
Accuracy
Class 0.5S (IEC 62053-22)
Harmonics
Up to 50th order
Sample rate
Up to 256 samples/cycle
Protocols
Modbus, BACnet, MQTT, OPC-UA
Standards
IEC 62053-22IEEE 519AS/NZS 61000.3
FAQ

Power & Load Monitoring — questions answered

Straight answers from our engineering team. Ask us directly →

Yes. We retrofit metering into live switchboards using split-core CTs and DIN-rail meters, in most cases without de-energising the main bus. We assess every retrofit against AS/NZS 3000 and the original board's type-test before proceeding.

Yes — we offer hosted Grafana dashboards with role-based access for your operations team, or we'll deploy the same stack on your own infrastructure if you prefer.

Absolutely. Three to six months of accurate sub-circuit data is the strongest position you can take into a retailer or DNSP tariff conversation. We provide the analytical packs.

Start a project

Build it right the first time.

Send us your scope, single-line, or RFQ. A senior engineer responds within one business day.